ABDF150KX / ABDF150KXF



Download Manual in PDF format


ABDF150KX / ABDF150KXF - 150W Full Ku-Band Block Up Converter   
Untitled Model

This unit features:

Output frequency 12.75-13.25 GHz & 13.75-14.50 GHz

Based on GaN technology which enables high efficiency, low energy consumption and high reliability

Double - L.O. (switchable 11.80 and 12.80 GHz)

Extreme P-Out GaN linearity

Auto-ranging power 90-240 VAC power options

Incomparable low power consumption (1070W max.)

Digital temperature compensation

L.O. lock and Amplifier LEDs

Digital temperature compensation

Field-exchangeable (F/N) IF connector

Advanced M&C - combined RS-232/485 / Ethernet (HTTP and SNMP ver. 2 & 3) / FSK (optional)

Internal 10 MHz high stability reference (optional)

RoHS compliant

Model

RF Frequency

Local Frequency

IF Frequency

Output Power

Connector

ABDF150KX

12.75 to 13.25 GHz & 13.75 to 14.50 GHz

11.80 & 12.80 GHz

950 to 1,700 MHz

150W (+51.76 dBm min.)

N-type

ABDF150KXF

12.75 to 13.25 GHz & 13.75 to 14.50 GHz

11.80 & 12.80 GHz

950 to 1,700 MHz

150W (+51.76 dBm min.)

F-type

Block Upconverters (BUCs)  /  Ku-Band   Manufacturer: Actox
Zoom In image Download full description in PDF format  Print page    Email this page to a friend(s)
  Price:  Contact Us
     EXIT  
  Availability:  Contact Us


Specification
Specification
Untitled Parameter

Parameter

Value

Output interface

Waveguide, WR-75

Output power

+51.76 dBm min. over temperature

Conversion gain

68 dB min, 72 dB nom.

Required frequency

External reference input power

Phase noise

10 MHz (sine-wave)
-5 to +5 dBm @ input port
-55 dBc/Hz max. @ 10 Hz
-65 dBc/Hz max. @ 100 Hz
-75 dBc/Hz max. @ 1 KHz
-85 dBc/Hz max. @ 10 KHz
-95 dBc/Hz max. @ 100 KHz
-115 dBc/Hz max. @ 1 MHz

Input V.S.W.R.

1.5 :1 max

Output V.S.W.R.

1.5 :1 max

Parameter

Value

Power requirement

90~240 VAC via MS connector, 1070W max.

Mute

Shut off the HPA in case of L.O. unlocked

Input interface

N-type or F-type

M&C

RS-232/485/Ethernet/
FSK (optional)

Power consumption

VAC - 1070W max.

Operating temperature

-40 to +60 degrees C

Storage temperature

-55 to +85 degrees C

Size

240 (L) x 202.4 (W) x 139.2 (H) mm

9.4" (L) x 7.9" (W) x 5.48" (H)

Weight

8.5 kg (18.7 lbs) max.